Using the Compucom Speedmodem with TELEMATE software

Using the Compucom Speedmodem with TELEMATE software:

This is by no means a technical document on all the different ways to
initialize your CompuCom Speedmodem for TM v2.11, but a SIMPLE guide...

oo ..Be sure the Speedmodem ROM version is at least 2.51. Type ATI3...
\/ ..from any communications program in TERMINAL mode for results...
   ..EXAMPLE: (c) Copyright CompuCom 1990 V2.51

   oo ..Press ALT O from the main menu...
   \/ ..choose DIAL SETUP from the Options Menu...
ÕÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ͸
³  General        ³
³ *Dial setup*    ³
³  Directory      ³
³  Terminal       ³
³  Communication  ³
³  Protocol       ³
³ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ³
³  Load options   ³
³  Save windows   ³
³  Save options   ³
ÔÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ;
oo ..Turn Auto Baud Detect OFF...
\/ ..[X]=on [ ]=Off
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³  [ ] Auto Baud Detect ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
ÉÍÍÍÍ»
º OK º
ÈÍÍÍͼ

   oo
   \/ ..choose TERMINAL from the Options Menu...
ÕÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ͸
³  General        ³
³  Dial setup     ³
³  Directory      ³
³ *Terminal*      ³
³  Communication  ³
³  Protocol       ³
³ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ³
³  Load options   ³
³  Save windows   ³
³  Save options   ³
ÔÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ;
oo ..Turn the X on for RTS/CTS...
\/
ÚÄ Control ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³  [ ] XON/XOFF Flow         ³
³  [X] RTS/CTS Flow          ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
ÉÍÍÍÍ»
º OK º
ÈÍÍÍͼ

   oo
   \/ ..Choose COMMUNICATION from the Options Menu...
ÕÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ͸
³  General        ³
³  Dial setup     ³
³  Directory      ³
³  Terminal       ³
³ *Communication* ³
³  Protocol       ³
³ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ³
³  Load options   ³
³  Save windows   ³
³  Save options   ³
ÔÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ;
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³                             vv +F Not used on roms after 4/1 ³
³  Modem Init String     AT&F2+F*H2%C0&C1&D2S0=0M1X4&W^M       ³
³  Modem HangUp String   ^#~~~+++~~~ATH0^M                     ³
³  Auto Answer String    +++~~~AT S0=1 Q1 E0^M                 ³
³  Answer Back String                                          ³
³                                                              ³
³                                                              ³
³  Port          ( ) COM1  ( ) COM3  ( ) COM5  ( ) COM7        ³
³                ( ) COM2  ( ) COM4  ( ) COM6  ( ) COM8        ³
³                                                              ³
³  Baud Rate     ( ) 300        ( ) 4800       ( ) 38400       ³
³                ( ) 1200       ( ) 9600                       ³
³                ( ) 2400       ( ) 19200... oo..LOCK...       ³
³                                            \/..BAUD...       ³
³  Parity        ( ) None       ( ) Even                       ³
³  Data Bits     ( ) 7          ( ) 8                          ³
³  Stop Bits     ( ) 1          ( ) 2                          ³
³                                                              ³
³                 ÉÍÍÍÍ»              ÚÄÄÄÄÄÄÄÄ¿               ³
³                 º OK º              ³ Cancel ³               ³
³                 ÈÍÍÍͼ              ÀÄÄÄÄÄÄÄÄÙ               ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

oo ..Lock the baud rate at ( ) 19200, set ( ) COMx properly.
\/

oo AT&F2 +F *H2%C0 &C1&D2 S0=0 M1 X4 &W ^M
\/ |     |  |      |      |    |  |  |  |
...|___| |  |____| |____| |__| |  |  |  ENTER (TM requirement).
...|     |  |      |      |    |  |  |
...|     |  |      |      |    |  |  Write to Firmware.
...|     |  |      |      |    |  |
...|     |  |      |      |    |  Wait for dial tone, saves ears!
...|     |  |      |      |    |
...|     |  |      |      |    Listen when ringing, optional.
...|     |  |      |      |
...|     |  |      |      Do not answer, see answer mode for TM.
...|     F  |      |
...|     A  |      Recommended for TM!
...|     X  |
...|     |  Depends on error mode wanted       ..............
...|     O  *H1 or *H2    (MNP-5)              ...REFER to...
...|     F  *H1 or *H2%C0 (MNP-4) -|Recommend  ... Manual ...
...|     F  *H1 or *H2\N0 (no MNP)-|either one ..............
...|     |
...|     For COMBO only, do NOT use on CHAMP. NOT USED on ROMS AFTER 4/1/91
...|
...A must for Speedmodem!

oo ..*H2%C0 can be substituted with other variations...
\/ ..as recommended in the Speedmodem manual...

oo ..If using the COMBO, add +F to the Initialization string...
\/ ..turns fax off on the COMBO, returns ERROR on the CHAMP...

ÉÍÍÍÍ»
º OK º
ÈÍÍÍͼ

   oo
   \/ ..Choose SAVE OPTIONS from the Options Menu...
ÕÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ͸
³  General        ³
³  Dial setup     ³
³  Directory      ³
³  Terminal       ³
³ *Communication* ³
³  Protocol       ³
³ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ³
³  Load options   ³
³  Save windows   ³
³  Save options   ³
ÔÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ;

   oo ..Press ALT D from the main menu...
   \/ ..choose F6 from the DIAL menu...
      ..REPLACE ALL BAUD rates with 19200.................
ÕÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ͸
³  Edit             F6  ³
³ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ³
³  Hang up       Alt-H  ³
³  Learn script  Alt-N  ³
ÔÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ;

ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³                                                              ³
³  Name      ABC #1                                            ³
³  Phone     939-6478                                          ³
³  Password  123                             Script            ³
³  Memo                                      Log               ³
³  Port          (.) Default                                   ³
³                ( ) COM1  ( ) COM3  ( ) COM5  ( ) COM7        ³
³                ( ) COM2  ( ) COM4  ( ) COM6  ( ) COM8        ³
³  Baud Rate     ( ) 300        ( ) 4800       ( ) 38400       ³
³                ( ) 1200       ( ) 9600       ( ) 57600       ³
³                ( ) 2400       (.) 19200      ( ) 115200      ³
³                                                              ³
³  Parity        (.) None       ( ) Even       ( ) Odd         ³
³  Data Bits     ( ) 7          (.) 8                          ³
³  Stop Bits     (.) 1          ( ) 2                          ³
³                                                              ³
³              ÉÍÍÍÍÍÍÍÍÍÍÍ»          ÚÄÄÄÄÄÄÄÄ¿               ³
³              º Next Page º          ³ Cancel ³               ³
³              ÈÍÍÍÍÍÍÍÍÍÍͼ          ÀÄÄÄÄÄÄÄÄÙ               ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

   oo
   \/ ..An EASIER way is to load TM.FON into an editor and globally...
      .............REPLACE ALL BAUD rates with 19200.................


ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ Dial ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»
º Enter dial list  ( 23 25 73 )                                     
º [Space] Select    [Left,Right] Prev/Next Display    [PgUp,Up]   Sc²
º [Enter] Redial    [Home,End]   First/Last Page      [PgDn,Down] Sc±
ºßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßßß±
º   #   Name                           Parameter Total  LastCall Mem±
º   1  ABC #1         oo ..REPLACE..    2400N810   132  04-06-91    ±
º   4  Compucom BBS   \/ ..WITH.....   19200N810    52  04-08-91    ±

Dialing out:

oo ..RTS-CTS ON, ALL BAUD at 19200, AUTO BAUD DETECT OFF...
\/
  ...When using a long distance carrier with the Speedmodem...
  ...call your LD customer service and ask if a "carrier code"...
  ...is needed for proper "bandwidth" on "asynchronous" connections...

oo ..An example where this code is needed is the US Sprint...
\/ ..FIBER OPTIC NETWORK, to access a ""full-bandwidth" line...
  ...the code 10333 is needed, that is dial 10333-1-800-000-0000...
  ...this ensures that the FULL bandwidth is available to you...
  ...otherwise, a sudden "No carrier" can result...

Well, this by no means covers all the ways to use TM with a Compucom
Speedmodem. But it should help you initially (pun?). If all else fails,
don't forget to read the doc's!